Learning objectives
- Understand the properties of light, colour temperature, intensity and the principles of illumination.
- Study how lighting affects well-being, visual comfort, mood and productivity.
- Know the main lighting technologies (incandescent, fluorescent, halogen, LED and smart lighting), their characteristics and applications.
- Analyse a space and choose lighting that fits its function and aesthetics.
- Combine natural and artificial light through daylighting strategies, window placement and fixtures.
- Create different moods using accent, task and ambient lighting.
- Apply energy-efficient fixtures and controls.
Class schedule
- Revision
- Watch videos
- Teach module
- Break
- Teach the lumen calculator
- Assignment
Light and lighting
Lighting design is a process: the planning of how light will be perceived in a space. It includes selecting light sources but should not start with them. What matters is not what makes the light but which objects and surfaces receive it. The key to successful lighting design is to decide what you want to light up, then work backwards to the solution.
Transmission of light
The eye and brain translate light into colour using sensors in the retina: rods, which respond to amounts of light, and cones, which respond to colour. Light travels from the primary source (the sun) to the object and then to the detector (the eye and brain). An object appears white when it reflects all wavelengths and black when it absorbs them all.
Psychological impact
The real challenge for the designer is the emotional impact of an interior, created by manipulating brightness contrast. Lighting design is not just illumination. It showcases different sections of a room.
- If all surfaces receive equal light, contrast is lost, which reduces productivity and can leave people listless and depressed.
- The quality of light, not the quantity, decides how people feel. People are more alert, energetic and positive on a sunny day, which brings bright highlights and crisp shadows.
- First identify the activities that will take place, then decide the degree of stimulation that will reinforce them, then set the brightness contrast that will deliver it.
- Some tasks benefit from high stimulation, which encourages participation, enjoyment, excitement and productivity. Others benefit from minimal contrast so people feel contented, focused and relaxed.
- Brightness contrast works like background music. It affects task performance, behaviour at work and play, and contentment, and it sets an emotional tone that either supports or undermines the activity.
A large proportion of diffuse light and a small amount of focused light. Everything gets similar emphasis, so no hierarchy forms between foreground and background. The space is low in stimulation and behaviourally neutral. It suits easy seeing, random circulation and flexible work surfaces.
A small proportion of diffuse light and a large amount of focused light. It makes patterns of light and shade and builds a deliberate hierarchy between foreground and background. It raises stimulation and evokes specific moods. A single spotlight on a stage is the extreme example.
Colour temperature
Colour temperature describes the characteristic colour of light, from the warm yellow of a candle flame at about 1900 K to the cool deep blue of the sky at about 10,000 K, measured in kelvin. Match the right bulb to the application.
| Type | Temperature | Use |
|---|---|---|
| Warm white | 2700 K to 3000 K | Same as a standard incandescent bulb. A direct substitute for background light in living areas, hallways and bedrooms. |
| Cool white | 4000 K | Offices, kitchens, laundries and workshops. The cooler, bluer light makes contrast easier to see and is ideal for reading lamps. |
| Daylight | 6000 K and above | Special applications such as retail or entertainment where a blue-white light is preferred. It gives high-quality colour rendition on the Colour Rendering Index (CRI). |
Reflectance and distribution
How light bounces off walls, ceiling and floor depends on colour (dark or light), surface (matte or gloss), texture (rough or smooth) and pattern (bold or subtle). Plush, pile and textured surfaces absorb more light than smooth, glossy, reflective ones. Dark colours absorb more light than light colours. Reflective materials such as mirrors, gloss paint, polished and metallic fabrics, crystal fittings and metal surfaces can create dramatic effects in a night club or bar.
Types of light
Natural light
At the start of a project, assess the amount and direction of natural light. Know whether the space is lit or in shadow at different times of day and through the seasons. This affects textiles too: the colour and fibre of a fabric depend on how much light reaches it, when and from which direction.
Evaluating light levels and quality means noting the orientation of the building, which affects light, heat, shadows and choice of materials and finishes. Light also changes how we see colour. Morning light is clear white and afternoon light can be gold or red.
Overhangs, awnings, louvered shutters, motorised blinds, block-out blinds, fully lined curtains and upholstered screens.
Sheer curtains, sheer blinds, cut-out screens, louvered blinds and louvered shutters.
Enlarge windows, remove window treatments, and line window recesses with reflective surfaces.
Artificial light
Artificial light has no constraints. In a flawlessly lit room you never see the light source, even if the fitting is beautiful. You see walls and ceilings washed with a glow, lamps glowing behind softening shades, pools of light on objects and patterns of light across walls that give dimension, whimsy and mystery. Do not be afraid to experiment.
- A low-hanging, shaded pendant just above eye level over a dining table gives an intimate setting. Balance it with ceiling spotlights turned to reflect off walls, so they do not shine in the eyes of diners.
- Two wall lamps at eye level on either side of a bathroom or dressing-room mirror give reflected light for a small room and highlight the face.
Sources of artificial light
With the global drive to improve energy efficiency, most countries are phasing out the traditional incandescent bulb. The replacements use less energy, last longer and save money without compromising style or quality of light. The four main sources are LEDs, fluorescent, halogen and incandescent.
| Source | Properties and uses |
|---|---|
| LED (light-emitting diode) | Energy efficient with very low heat output. Extremely long lasting (50,000 to 100,000 hours). Expensive to buy, and the price reflects quality. Available as downlights, spotlights, globe bulbs, decorative candle bulbs, wall lights, stair footlights and flexible or rigid coloured strip lights for indoors or out. Warm white, cool white or daylight. Dimmable. |
| Fluorescent | Low energy use and long life (6,000 to 15,000 hours). Good for ambient or mood lighting, in warm white, cool white or daylight. Fits conventional bayonet or screw sockets and can replace incandescent bulbs in most fittings. Standard CFLs do not work on a dimmer circuit; only dimmable spiral CFLs do. They take time to reach full brightness, so are not suited to toilets and bathrooms where instant light is needed. New-generation fluorescent can light the back of a translucent screen or the inside of a coffer evenly to give a convincing soft daylight effect. |
| Halogen | Ideal for spot and task lighting over work surfaces because the built-in reflector gives a narrow beam. Used for accent and mood lighting in dining and living areas. The narrow beam goes down to the floor rather than reflecting off walls and ceiling, so it can make a space look smaller. Dimmable. CRI of 100, so colour and texture look true. Recessed and flush-mounted halogen ceiling lights need a 12 V transformer and a ceiling cavity of at least 15 cm. Clear halogen can be bright and piercing, so shade it or bounce it off another surface, and use it together with other fittings to keep a soft, even level. |
| New-generation halogen | A direct replacement for the standard incandescent lamp that lasts about twice as long and is about 30% more efficient. Costs more. Works with dimmers, sensors and electronic switches and gives instant light. |
| Specialist halogen | Lamp bulbs for task lamps and candle bulbs for decorative lighting. Oils from your fingers shorten the life of the bulb, so avoid touching the glass when replacing. |
| Incandescent | Long the dominant source in older homes. Warm, yellowish and flattering to the complexion, ideal for background lighting, with a narrow pool of light so watch for hot spots. The least efficient source: most energy leaves as heat. Replace with warm white CFLs or new-generation halogen to keep the colour tone and gain efficiency. |
Types of artificial light
The primary choice, around which all others fall in. It provides background lighting for safety and general activity and supplements natural light. It is usually a fixed, dimmable pendant in the centre of the room or a number of recessed ceiling lights that diffuse light over walls and ceilings. On its own it is indirect and lacks interest, so combine it with uplights, wall sconces and floor or table lamps to produce light and shade.
A concentrated beam of bright light on a surface for a specific job: food preparation, shaving, working, reading or playing an instrument. Fixtures are either installed (hardwired, such as pendants over desks or kitchen work areas, wall sconces or floor-level stair lights) or mobile (desk and floor lamps that plug in). The source should be hidden to avoid glare and sit in front of or beside the person so shadows do not fall on the work.
Targets decorative features for visual effect: artwork, accessories, shelves, collections, stairs and architectural features. It can be set into floor, walls or ceiling. Spotlights are common, but wall lights, downlights and lamps also work. Dark walls absorb light from above, so use wall lights that shine up and reflect off a light ceiling. Dimmers help set the atmosphere.
Ambient light should be relatively low level so it does not compete with task and accent lighting.
Light levels and lighting calculation
Different spaces need different light levels, which is why using several lighting effects in one space is advisable. Lighting must be worked out on a plan before it is installed, even if the fixtures need no electrical work. A lighting plan sits directly over the floor plan and carries a legend or key of electrical symbols.
Calculating the total light needed is the quantitative side of lighting. The lumen method is the most common: establish the intended use of the space, then measure its area.
| Term | Meaning |
|---|---|
| Lumen | The total quantity of visible light a source emits, also called light output or brightness. A standard 100 W incandescent bulb produces about 1,500 to 1,700 lumens. |
| Lux | Illuminance: lumens per square metre. |
| Efficacy | Lumens produced per watt consumed. The higher the number, the more efficient the bulb. |
| Watt | Not a measure of brightness but of how much electricity the bulb uses to reach its claimed brightness. Each source has a different lumen-per-watt ratio. |
| Wattage equivalence | A 100 W incandescent gives about 1,500 lumens, and so does a 10 W LED. |
As a guide, an average 23 m² (250 sq ft) room needs roughly 2,500 to 5,000 lumens as its primary light source, about 110 to 215 lumens per square metre. Over a dining table you want about 325 lumens per square metre. A table of 1.8 × 0.9 m is about 1.7 m², so around 540 lumens. These figures assume typical conditions and 2.4 m (8 ft) ceilings. With especially dark walls and furniture, or with shaded fixtures, add roughly 110 lumens per square metre. Personal preference matters: if you like a room bright, add 10 to 20%. For most spaces, aim high and install dimmers.
Recommended lux levels: residential
| Space | Lux | Notes |
|---|---|---|
| Living room (general) | 100 to 200 | Ambient, relaxing light |
| Living room (reading, tasks) | 300 to 500 | Task lighting near seating |
| Dining room | 200 to 300 | Higher over the table itself |
| Kitchen (general) | 300 to 500 | Ambient |
| Kitchen (countertop, task) | 500 to 750 | Preparation and cooking zones |
| Bedroom (general) | 100 to 150 | Ambient |
| Bedroom (reading) | 300 to 500 | Bedside task lighting |
| Bathroom (general) | 200 to 300 | Ambient |
| Bathroom (mirror, vanity) | 500 | Grooming tasks |
| Home office or study | 500 | Desk-level task light |
| Hallway or stairs | 100 to 150 | Circulation and safety |
| Closet or storage | 100 | Basic visibility |
| Garage | 100 to 300 | Higher if used as a workshop |
Recommended lux levels: commercial
| Space | Lux | Notes |
|---|---|---|
| Reception or lobby | 200 to 300 | Welcoming, moderate |
| General office (open plan) | 300 to 500 | Standard task lighting |
| Executive office | 300 to 500 | Sometimes with accent lighting |
| Conference or meeting room | 300 to 500 | Adjustable for presentations |
| Retail (general) | 300 to 500 | Ambient store lighting |
| Retail (display, feature areas) | 750 to 1,500 | Highlighting products |
| Supermarket | 500 to 750 | Even, bright coverage |
| Restaurant (dining area) | 100 to 300 | Mood-dependent, often dimmable |
| Restaurant (kitchen) | 500 to 750 | Food preparation, safety |
| Hotel guest room | 100 to 300 | Like a residential bedroom |
| Hotel corridor | 100 to 150 | Circulation |
| Classroom | 300 to 500 | Reading and writing tasks |
| Library (reading area) | 300 to 500 | Task-focused |
| Hospital (general ward) | 100 to 300 | Ambient patient care |
| Hospital (operating room) | 1,000 to 20,000+ | Surgical task lighting, highly specialised |
| Warehouse (general) | 100 to 200 | Storage and circulation |
| Warehouse (picking, packing) | 300 to 500 | Task areas |
| Industrial workshop | 300 to 750 | Depends on the precision of the work |
| Parking garage | 50 to 100 | Circulation and security |
Simple formulas
Total lumens = Area (m²) × Required luxArea is length × width. Example: a 4 m × 5 m office is 20 m² and needs 300 lux, so 20 × 300 = 6,000 lumens. Take the lux value from the tables above.
Number of fixtures = Total lumens required ÷ Lumens per fixtureExample: 6,000 lumens needed and one LED bulb gives 800 lumens, so 6,000 ÷ 800 = 7.5, which rounds up to 8 bulbs. Always round up.
Watts per fixture = Lumens of bulb ÷ Efficacy (lm/W)
Total watts = Number of fixtures × Watts per fixture
Energy (kWh) = Total watts × Hours used per day ÷ 1000Example: 8 LED bulbs at 10 W each is 80 W. Used 5 hours a day, that is (80 × 5) ÷ 1000 = 0.4 kWh per day.
| Bulb type | Typical efficacy (lm/W) |
|---|---|
| Incandescent | 10 to 17 |
| CFL | 50 to 70 |
| LED | 80 to 100+ |
Spacing between fixtures = SHR × Mounting height
Fixtures per row = Room length ÷ Spacing
Number of rows = Room width ÷ Spacing
Wall offset = Spacing ÷ 2The spacing-to-height ratio (SHR) is typically 1 to 1.5, so check the manufacturer’s spec sheet. Mounting height is measured from the fixture to the work plane, usually about 0.85 m above the floor. Example: mounting height 2.5 m and SHR 1.5 give spacing of 3.75 m. In an 8 m × 6 m room that is about 2 fixtures per row and 2 rows, so about 4 fixtures. The distance from the wall to the first fixture is half the spacing, which prevents dark corners. Cross-check with the lumen method.
Light distribution. After you know the lumens a space needs, decide the lighting sources and fixtures, and the lumen output of each fixture.
Improving energy efficiency
- Switches. Locate switches at the entry and exit points of a room. Use two- or three-way circuits where a room has several entrances, and put switches at the top and bottom of a stairwell. Give each lighting installation its own control, since one switch for all lights wastes energy. Put task and accent switches next to the task area so they are used only when needed.
- Sensors. Movement sensors turn lights on when someone enters and off when they leave. There are two types: motion detectors and presence detectors.
- Dimmers. Dimmable circuits and layering several kinds of light change the mood of a room. Dimmers also save energy and extend bulb life by reducing output.
Lighting your home
The first impression. A well-lit path leads visitors from the street or driveway to the door. Choose fittings that suit the architectural style, keep light around the door brighter than the surrounding landscape lighting, add a feature such as a planter to make it welcoming, and consider security lighting as a deterrent.
A restricted area with little room for furniture, so use lighting for visual impact. Use ceiling or wall lights for ambient light, uplights for drama and spotlights on artwork. A large pendant or chandelier suits a void or stairwell. A narrow console with a table lamp gives soft warm light. Put a switch near the front door, and use a dimmer to help the eye adapt.
Many activities happen here, so lighting must be practical, attractive and flexible. Dimmed recessed downlights give a softer atmosphere. Add floor lamps, table lamps and uplights for general light, task lighting for reading and hobbies, and accent lights for artwork. A variety of lights prevents monotony.
Good light is essential for enjoying food. A pendant gives a focal point and a broad spread of light over the table, but its shape and height must avoid glare and not block conversation. Dim it for intimacy. Table lamps and low-wattage uplighters soften the evening mood.
The main task area, often open plan. Plan task lighting over benches first, then ambient light. Use adjustable halogen spots to avoid working in your own shadow, downlights or pendants over an island, and fluorescent strips in pantries and under wall cupboards. Use accent light on splashbacks and under island benches. Good colour rendering is essential for food preparation. Lights must meet the electrical code for a damp area.
A restful environment for sleep. Use soft ambient light for relaxing and watching TV, and task lighting for reading, writing and make-up. Bedside lamps and dimmable wall lights or uplights behind the bed give background light. A children’s room can have a small shaded low-wattage lamp or a plug-in night light.
Light stairs well for safety and to avoid hazardous shadows. Small lights recessed into the wall or treads define the path and make a feature of the stairwell. Pendants from the first floor and wall lights also work.
Bathrooms: lighting and electrical safety
Bathrooms are wet areas, so the safety of light fittings is paramount because electricity and water are close together.
- Fixtures within a set distance of a shower, bath or basin must be sealed or closed to prevent water and steam damaging the wiring.
- An Ingress Protection (IP) rating shows suitability. In IP54, the first digit (5) means protected against dust and the second (4) means protected against splashing. The higher the number, the better the protection.
- Control ambient light with a dimmer for a relaxing bath.
- Lights on either side of the mirror give even, glare-free light for shaving or make-up. A light above the mirror is not flattering because it casts shadows on the lower face.
- Residual current devices (RCDs) are used in bathrooms in place of a standard power outlet. They are a legal requirement in bathrooms and other damp areas in new homes, or where a new circuit from the switchboard is added to an existing home.
- Extraction fans are essential in wet areas (kitchen, bathroom, laundry). They must vent to the outside through the ceiling or an outside wall, so damp air does not recirculate and cause mildew.
Lighting terms and definitions
| Term | Definition |
|---|---|
| Ballast | Electrical or electronic component required to start and operate fluorescent lamps. |
| CRI | Colour Rendering Index, on a scale of 1 to 100 with 100 ideal. The ability of a light source to render the colour of an object accurately compared with natural light. |
| Colour temperature | The warmth or coolness of white light, measured on the Kelvin scale. |
| Cove lighting | Lighting, usually fluorescent or LED, built into a shelf or ledge high on a wall to illuminate the ceiling. |
| Dimmer | A control that lowers the light level to change the mood. It also saves energy and extends bulb life. |
| Gimbal lighting | An adjustable ring that holds a halogen or LED downlight by its rim so the direction of light can change. |
| GPO | General Purpose Outlet or General Power Outlet: what you may know as a power point. It can only be installed or maintained by an electrician. |
| Hardwired | A fixture permanently connected to an electrical source, with no visible cord or plug. |
| Heat rating | Recessed downlights and surface-mounted fixtures must pass heat tests so they do not affect combustible ceiling materials. This limits the maximum safe wattage. |
| IP rating | Ingress Protection. The first digit shows how dust proof a fitting is and the second how waterproof. Important for wet areas and outdoor lighting. |
| Kelvin scale | Colour temperature scale. Lower ratings are warm and yellow, higher ratings are cooler and bluer. |
| Kilowatt hour (kWh) | A unit of electrical energy. One kWh is 1000 watts used for one hour. |
| Lumens | The amount of light a bulb produces. |
| Luminaire | A complete lighting unit including lamp, housing, ballast, sockets and other necessary components. |
| Lux | The unit of illuminance, in lumens per square metre. |
| Recessed downlight | A circular or square fixture set into the ceiling that concentrates light downward. |
| Retrofit | Replacing existing fixtures with new technology that improves efficiency or safety. |
| Three-way switch | Operates a fixture from two locations. |
| Transformer | Converts one voltage to another. Many halogen ceiling fixtures need one. |
| Wall lighting | Lighting directed onto a wall to emphasise the plane, enhance texture or bounce light back into the room. Brighter walls generally make a room seem more spacious. |
| Wall washing | A technique that washes a wall evenly with light. |
| Watt | A unit of electrical power. |
| Wattage | The electricity a bulb consumes. For devices, the maximum watts they are designed to deliver or control. |
Assignment: lighting and electrical plan
Choose one of two options. Imagine your lighting plan sitting directly over your floor plan.
- Option A. Continue from the plan you created in Assignment Four and draw a plan for lighting and other electrical equipment.
- Option B. An architectural plan is provided so you can follow a real workflow for lighting system design. Draw a lighting plan for the sample (100 marks).
- Plan power sockets for all kitchen appliances and white goods (fridge, microwave, stove, dishwasher) and for entertainment and computer equipment.
- Research what technology and appliances are available in your country and the constraints and requirements for installing them.
- The existing house is over 60 years old and has its original electrical work and switching. Show your fixtures, outlets, switches, dimmers, wiring and anything else your electrician needs.
- You do not need to include flooring or furniture, but label every room and include a lighting legend or key.
- Draw by hand, scan and upload as a JPEG or PDF, or draw digitally.
Recommended reading
- Interior Lighting for Designers by Gary Gordon (Wiley, 4th edition, 2003)
- Lighting Design Basics by Mark Karlen and James R. Benya (Wiley, 3rd edition, 2017)
- Residential Lighting: A Practical Guide by Randall Whitehead (Wiley, 2003)
- Lighting for Interior Design by Malcolm Innes (Laurence King, 2012)
- Designing with Light by Jason Livingston (Wiley, 2014)
- Fundamentals of Lighting by Susan M. Winchip (Fairchild Books, 3rd edition, 2017)
- Sustainable Lighting Design by Kyle Konis and Stephen Selkowitz (Routledge, 2020)
- The Lighting Handbook, Illuminating Engineering Society (10th edition, 2011)